Skip to main content

The inductive sensors follow the standard M12 and M18 industry design, and offer a wider detection range with the same dimensions to provide easier and faster installation.
Detection range: 2 ~ 12mm

Features & Benefits
Nickel coated brass

Standard sensors for ferrous metals detection
IP67 and CE certification
Electrical circuit protection

Specifications
Sensing distance: 2 mm ± 10%, 4 mm ± 10%, 5 mm ± 10%, 8 mm ± 10%,12 mm ± 10%

Differential Travel: max. 10% of sensing distance
Detectable Object: Ferrous metal
Power Supply Voltage (Operating Voltage Range): 12 to 24 VDC, ripple (p-p): max. 10%
Current Consumption: 15 mA max
Output:
– Load current: 200 mA max
– Residual voltage: 2V max. (load current: 200 mA, cable length: 2 m)
Indicators: Operation indicator (red)
Operation Mode (with Sensing Object Approaching): NPN: NO / NC; PNP: NO / NC
Ambient Temperature Range:
– Operating: Operating: -25 ~ +70 ºC / storage: – 40 ~ 80 ºC (with no icing or condensation)
Connection Method: 3 wires 2m cable and M12 connector with 200mm cable

Applications
Food and beverages, packaging, pharmacy, electronic component equipment, textile, rubber and plastics, warehouses, machine tool industries